MSA Orion Multigas Detector (LEL / O2 / CO / H2S) with NiMH Battery Pack, Charger, Econo-Cal Check Gas, Flow Regulator and Hard Case
| Model | Orion Multigas Detector |
| SKU | INTSMA00066 |
| Condition | Surplus — As Removed |
| Stock Qty | 1 |
| Hazardous Area | Yes — ATEX / IECEx |
| Certifications | DMT 01 ATEX E 001 X (CE 0080), AUS Ex 01.3730X, UL classified Class I Div 1 (C22.2 No. 152), RCM mark N10132 |
| Origin | USA |
| Category | Gas Detection & Hazardous Area |
Description
MSA Orion
is a portable multigas detector that samples the air with an internal pump. It reads combustible gas (%LEL), oxygen, carbon monoxide and hydrogen sulfide on a two-window LCD, and is used for confined-space entry, hot work and general gas safety checks. This is a complete carry-case kit with its calibration accessories.- MSA Orion Multigas Detector with a two-window LCD, a large POWER / page button, an alarm reset / scroll button and four sensor ports on top. The display legend in the quick card shows %LEL, %O2, ppm CO and ppm H2S.
- NiMH battery pack P/N 10031091 fitted (max. 10 V, 3 A). The label also lists alkaline battery use (-20 to +50 °C).
- Rear belt clip.
- Hazardous-area markings: II 2G EEx ia d IIC, NiMH T3/T4 (-20 to +50 / +40 °C), alkaline T3/T4 (Varta / Energizer T3, Duracell T4), CE 0080, DMT 01 ATEX E 001 X. Also AUS Ex 01.3730X, and a UL classification for Class I Div 1 Groups A, B, C, D with battery packs 10031091, 10031092 and 10042020.
- MSA charger / power unit EGSTON L2xFSW (MSA #10020551 Rev 6): in 100–250 V 50/60 Hz, out 3.6 V 1.5 A, with LED charge status. Australian IEC mains lead supplied.
- MSA Econo-Cal calibration check gas cylinder (non-refillable, 34 litres, supplied in Australia by Air Liquide): 300 ppm CO, 1.45 % methane (58 % LEL pentane simulant), 15 % O2 and 10 ppm H2S, balance nitrogen, 500 psig.
- MSA flow control regulator, 0.25 L/min, with pressure gauge and yellow tubing.
- Manuals: Orion Operation Manual (English / Spanish / French, P/N 10021555 Rev 5, 2003), Instruction Manual Addendum (2001), Quick Reference Card, a display legend card, an emergency procedures sheet and a small zip bag of accessories.
- Black hard case with moulded foam inserts.
- Sold as surplus, as-is where-is.
Used surplus kit in its original foam-lined case. The detector has scuffs, light wear and general handling marks, and the LCD is blank in the photos. Not powered up, calibrated or bump tested by Sunrise Marine. Sensor life and battery condition are unknown. The check gas is old stock and may be out of date. Recalibration and a sensor check are recommended before use.
Related Items
Thompson Maxseal ICO3S DUAL-SEAL Explosion Proof Solenoid Valve Y013AA3H1BS 24V
Honeywell Searchpoint Optima Plus 2108B2001N ATEX IECEx HC Gas Detector NEW 2024
Hawke International S1 ATEX IECEx Hazardous Area Junction Box 20-Way Terminal
Request a Quote
We respond within 1 business day with availability, pricing & shipping.